International Arab Journal of Dentistry
DOI
https://doi.org/10.70174/iajd.v16i1.1389
Abstract
Introduction: The aim of this study was to compare the accuracy of apical gauging using NiTi K-files and gutta-percha cones and determine the level of agreement between the two methods using a Scanning Electron Microscope (SEM).
Methods: 75 circular and straight canals of mandibular first premolars were used. Canals were shaped using the R-Motion system (RM; FKG Dentaire, La Chaux-de-Fonds, Switzerland) and gauged using NiTi K-Files and gutta-percha cones matching the shaping instrument. Diameters measured on SEM images were used as the reference standard.
Results: There was a statistically significant difference in the prediction of apical diameter by gauging with both NiTi K-Files (P
Conclusions: NiTi K-Files and gutta-percha cones have similar accuracy but are not accurate in gauging the apical foramen.
Recommended Citation
Slim, Marie-Louise; El Hachem, Roula; Nasr, Lara; Zouein, Romy; Mhanna, Rami; Karam, Mia; and khalil, issam
(2025)
"Evaluation of the Accuracy of NiTi K-Files and Gutta-Percha Cones in Gauging the Apical Foramen Using the Scanning Electron Microscopy: A laboratory study,"
International Arab Journal of Dentistry: Vol. 16:
Iss.
1, Article 6.
DOI: https://doi.org/10.70174/iajd.v16i1.1389
Available at:
https://digitalcommons.aaru.edu.jo/iajd/vol16/iss1/6